Home > Cập nhật thông tin tổng hợp > Fanuc Program Errors (P/S Alarms)

Fanuc Program Errors (P/S Alarms)

Program Errors (P/S Alarms) (for Fanuc )


Number Contents
000 Re-apply  the power  after the parameter was input.  (Parameter  No.  06  to 10,
I5 to 20,   31 to 37,   61 to 63).
001 TH   alarm    (A   character   with   incorrect   parity   was   input).    Correct   the tape.
002 TV   alarm   (The  number  of  characters  in  a block  is odd).    This  alarm  will be  generated
only when the TV  check is effective.  Correct the  tape.
003 Data exceeding  the maximum  allowable number of digits was input. (Refer to
the item of max programmable dimensions.)
004 A numeral or the  sign   “-”  was input without  an  address at the beginning
of a block.
005 The address was not followed by the appropriate data but was  followed by
another address or EOB code.
006 Sign “-” input  error  (Sign   “-”   was  input  after  an  address with which  it
cannot be used.   Or two or more “-”  signs were input.)
007 Decimal   point  “.”  input   error   (A   decimal   point   was   input   after   address
with which it  can not be used.   Or two decimal points were input.)
009
Unusable  character  was input in  significant  area   (A,   B,   C,   D,   E,   L,   U,
V,  W)
010  An unusable  G  code was commanded.
011 Feedrate was not command at cutting  feed or the feedrate was inadequate.
015 The    number    of    the    commanded    axes  exceeded    that    of    simultaneously
controlled axes.
021 The axis not included in the selected plane   (by using G17,  G18, ;G19)  was
commanded in circular interpolation.
029 The offset value specified by H code is too large.
030 The   offset   number  specified  by   H   code   for  tool   length   offset   of   cutter
compensation is too large.
For upgrading to dripfeed (DNC) or other information on Fanuc 3M controls
(parameters, alarm codes etc), please visit our website at Fanuc3Mdripfeed.com
Page 1 of 4
Fanuc3Mdripfeed.com  –  supporting the global Fanuc 3M users community
Number Contents
031 In setting of offset amount by G10,  the offset number following  address P was
excessive or it was not specified.
032 In setting of offset amount by  G10,  the offset amount was excessive.
033 A point of intersection can not be determined for cutter compensation C, Or cutter
compensation   B  was  programmed  on  the  inside  corner  less  than 90°.
034 The  start  up or cancel was  going  to be performed  in  the  G02  or  GO3  mode in
cutter compensation  C.
035 G39   is   commanded   in   cutter   compensation   cancel   mode   or   at   the   plane  other
than offset plane.
036 Skip cutting  (G31)  was  specified in cutter compensation  C mode.
037
G40 (offset cancel) is commanded at the plane other than offset plane. The
plane selected by using G17, G18 or G19) is changed in cutter compensation C
mode.
038 Over-cutting  will  occur  in  cutter  compensation  C  because  the  arc  start point
or end point coincides with the arc center.
041 Over-cutting will occur in cutter compensation.
044 One of G27 to G29 is commanded in canned cycle mode.
059 The   program  with   the  selected  number  cannot  searched,  in  external program
number search.
060 Commanded  sequence number  was  not  found in the sequence number search.
070 The memory area is insufficient.
071 The address to be searched was not fount. Or the program with specified program number
was not found in program number search.
072 The number of programs stored exceeded 63.
For upgrading to dripfeed (DNC) or other information on Fanuc 3M controls
(parameters, alarm codes etc), please visit our website at Fanuc3Mdripfeed.com
Page 2 of 4
Fanuc3Mdripfeed.com  –  supporting the global Fanuc 3M users community
Number Contents
073 The commanded program number has already been  used.
074 The program number is other than   1  to  V999.
076 The   address   P   was   not   commanded   in   the   block   which   induces   a   M98
command.
077 The  subprogram was called in triple.
78 The     sequence    number   which    was    specified  by  address  P  in  the block which
includes an M98 or M99 was not found.
79 The  contents of the program  stored in  the  memory  did  not  agree with that  in  tape
in  collation.
85
When   entering  in  the  memory by  using   ASR  or   RS232  interface, an over-run   or
framing   error   was   generated.   The   number   of  bits  of input data or  setting  of baud
rate is incorrect.
86 In   entering   in   the  memory  by  using   RS232C  interface,  the   ready signal (DR)  of
I/O devices was turned off.
087
When  entering  data in the memory by  using   RS232C  interface,   though  the  read
terminate   command   is   specified,   input   is   not  interrupted   after  10 characters
read.
090
The   reference   point   return   cannot   be   performed   normally  because   the reference
point   return   start  point  is   too   close   to   the   reference   point   or the speed is too
slow.
92 The  commanded  axis  by  G27  (reference  point  return  check) did not return to the
reference point.
100 The switch to set parameters was turned on. Push  the reset button after turning
off the switch.
101
The power was  turned off while  rewriting  the  contents  of  the  memory  in the  part
program   storage   &  editing  operation.   When   this   alarm  is   generated, you must
turn on the power while pushing the [DELET] and [RESET] buttons to clear the memory.
111
The   operation   result   of   macro   instruction   exceeds   the   allowable   range
(-232  to  +2 32  -1)
For upgrading to dripfeed (DNC) or other information on Fanuc 3M controls
(parameters, alarm codes etc), please visit our website at Fanuc3Mdripfeed.com
Page 3 of 4
Fanuc3Mdripfeed.com  –  supporting the global Fanuc 3M users community
Number Contents
112 Division is 0.  (including the case of tan 90°)
114 In the block with G65,  the undefined H code is specified.
115 The variable number of the undefined variable is specified.
116
The   variable   with   variable   number   which   was   specified   by   address   F   is
prohibited to substitute the value.
119 The argument of SQRT or BCD is negative value.
125 In the block with G65,  the unusable address was specified.
128
The sequence number specified in the branch  command was not  0  to 9999.
Or,  it cannot be searched.
For upgrading to dripfeed (DNC) or other information on Fanuc  controls
(parameters, alarm codes etc), please visit our website at Fanuc dripfeed.com

  1. No comments yet.
  1. No trackbacks yet.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: